Harness Upgrade from Rev 1 to Rev 2
This upgrade kit includes the A200-DDC Rev C required for the harness upgrade, all wiring and installation instructions. After installation the Rev 1 instrument will function in an identical way as the Rev 2 instrument.
These units are TSO qualified with all 200 Series instruments and is STC'd as a primary replacement instrument component under all flight conditions (day/night VFR and IFR).
 Certification / Compliance
 TSO (various per instrument)
 Canadian STC
FAA STC
Certified as primary replacement
Environmental
 DO-160F A1CAASXXXXXXZBXXBBBCSBA1C11XXAX
DC Power Source
 Input voltage 6 to 36 VDC
 Power consumption 10mA (maximum brightness)
 Load dump tolerance +60V
 Direct spike tolerance +/- 60V
 Cable spike tolerance > +/- 1KV
Operating Temperature
 Constant operating -15ºC to +55ºC
 Short term operating (1hr) -40ºC to +70ºC
 Storage -55ºC to +85ºC
Signal Output
0.0V to Bus Voltage 
Dimensions
0.5" diameter with 1/4" mounting hole
Weight (including knob)
 1.0 oz